Filter Results By:

Products

Applications

Manufacturers

Showing results: 16 - 29 of 29 items found.

  • High Speed Optical Power Meter

    Shenzhen Golight Technology Co.,Ltd

    High-speed optical power meter has fast sampling and data cache functions, and supports external trigger input and analog output. It is built-in 2mm or 5mm photosurface detector, and has wide dynamic range and high measurement accuracy, can be applied to various optical loop test solutions.

  • Multifunction Electrical Installations Meter

    MPI-520 - Sonel S.A.

    The MPI-520 multifunction meter is dedicated to perform diagnosis of electrical installation according to IEC 61557 standards. Digital meter MPI-520 is designed to measure impedance of a short cicuit loop also without triggering RCD, parameters of RCD, insulation resistance, earthing resistance, continuity and also for phase sequence testing. Furthermore to measure and logging of AC voltage and current, frequency and power.Wide range of standard accessories enable to perform all necessary measurements and safety test. Highly professional portable multifunction meter with memory of measured parameters.

  • Carrier to Noise Generators

    CNG-DX - Hollis Electronics Company LLC

    CNG-DX provides improved noise generation with its internal digital power meter and built-in noise generator. This single instrument provides accurate and repetitive carrier-to-noise setting ability in one box. The CNG-DX is an ideal instrument for creating realistic scenarios for closed loop testing of satellites, ground equipment and mobile transceivers.

  • Relative Humidity & Air Temperature

    A70-HT - Comptus

    The A70-HT provides analog output signals proportional to relative humidity and air temperature. The A70-LPDD loop indicator can be used to display the sensed relative humidity and temperature with the 4-20 mA output. These units are used in conjunction with electronic data collection systems or for input to control systems. They are readily combined with meter relays to provide custom controls.

  • Field Strength Meters

    FIM-22 And FIM-41 - Potomac Instruments, Inc.

    The Models FIM-22 and FIM-41 are portable field strength meters designed to provide precise, direct measurements of electro-magnetic fields in the 200 kHz to 5.0 MHz spectrum. These units include a receiver, integral shielded loop antenna, precision attenuator, internal calibration source, and battery power supply. With calibration accuracy traceable to the National Institute of Standards and Technology, the FIM-22 and FIM-41 meet the most exacting requirements of government and industry. Their hinged covers, on the rugged drawn aluminum cases, contain a loop antenna. Opening the cover to a vertical position connects the antenna terminals to the receiver via maintenance-free gold-plated contacts. An interlock switch prevents inadvertent battery discharge when the cover is closed.

  • Ground Fault Finder

    FST-JD200 DC - Foresight Electronics Co., Ltd.

    FST-JD200 not only can provide a solution on accurately testing the faults of the indirect-grounding of the direct current system, non-metal grounding, loop grounding, simultaneous grounding of the anode and cathode, balanced grounding of the anode and cathode and multi-point grounding 1. The high-precision sampling clamp meter The device uses a high resolution (0.1mA) signal sampling direct current clamp meter that can achieve multi-point grounding and high resistance ground point positioning...

  • Linear regulated power supply with thyristor pre-regulation

    NTN - FuG Elektronik GmbH

    High efficiency Short circuit proof and unlimited operation with full current in short circuit condition voltage and current regulation with automatic and sharp transition; control mode indicated by LEDs Voltage and current setting with 10-turn potentiometers with precision scale; the adjusting knob can be locked 4 digit DVM for voltage and current (for table-top models) Sense terminals for the compensation of voltage drop on the load lines. The nominal voltage always refers to the output terminals Parallel and series connection possible Suitable for inductive and capacitive loads for 700 W nominal power and higher, limitation of inrush current on switching on Interlock loop to monitor the external load and internal loop as a standard for three phase units Elapsed-hour meter as a standard for three phase units

  • Digital Multimeter, USB Interface, 20000 Count, True RMS, Auto Range, 4.5 Digit

    72-7730A - Tenma

    Digital multimeter is a 20,000 counts and 4-1/2 digits with steady operation. The meter can measure AC voltage and current, DC voltage and current, resistance, capacitance, temperature frequency, diodes, continuity, 4 to 20mA loop, Max/Min, relative mode but also has data store, data recall, AC true RMS, AC+DC, low battery display, double display backlight, automatic power off and full overload protection.

  • QAM And PCM Analyzers

    GAO Tek Inc.

    GAOTek provides a wide range of high performance and inexpensive QAM/PCM analyzers. Quadrature amplitude modulation (QAM) and pulse code modulation (PCM) analyzers are convenient instruments with top to bottom estimations and adaptable setups. Additionally, these devices have integrated functions of  analog signal generators/receivers, BERT, signaling generators/receivers, selective level meters, ring generators/ identifications, dialers, DC loop circuits (ICT, OGT), balanced bridges and reflecting bridges into solitary instruments. These analyzers are ideal for installing and maintaining digital and analog networks.

  • Earth Leakage Relay

    Nippen Electrical Instruments Co.

    NIPPEN's Earth Resistance Testers are used for measuring earth electrode resistance, soil resistance, earth continuity, neutral and earth loop resistance, resistance of various components etc.They are used in Railways, Defence, Utilities, Power Plants, Geological Surveys and other Industries.Direct reading type models SET/DET/TET provide direct readings of resistance on moving coil type meters, having a linear scale, 70mm long knife edge pointer and an external zero adjustment.

  • H/L Voltage Clamp Meters

    MEWOI Electronics Co.,ltd

    High Voltage Current Transformation Ratio Tester breaks traditional structure, specially designed for high and low voltage first and secondary loop current, variable ratio, and current leakage test; apply the latest CT technology and mask digital integration technology, composed of special high-voltage clamp, low voltage clamp, host, high voltage insulation rod and monitoring software, etc; its wireless transmission test data can penetrate multiple building obstacles with a straight-line distance of 30 meters.

  • Handheld RF Power Meter

    V3500A - Keysight Technologies

    The V3500A Handheld RF Power Meter is a compact, handheld instrument that makes accurate RF power measurements in both field and manufacturing applications. With an absolute accuracy as good as 0.21dB, a wide frequency range of 10MHz to 6GHz, and a measurement range of -63dBm to +20dBm, the V3500A is suitable for a wide variety of RF measurement applications. Its built-in power sensor eliminates the need for users to carry both an instrument and a separate sensor module. Truly portable, the V3500A fits easily into your hand or a toolkit. An optional belt loop holster or carrying case with shoulder strap is also available. To optimize flexibility, it is capable of drawing operating power from batteries, an AC-DC converter module, or a computer via USB interface.

  • Installation Safety Testers

    PeakTech Prüf- und Messtechnik GmbH

    This innovative combination meter for testing electrical installations according to VDE 0100 convinces by its technical performance in the high-end range.With the large 3.5 "TFT color display all important safety checks as the RCD-, Voltage-, Loop-, Low-Ohm, Earth resistance and Insulation tests for annual safety-checks and newly installed systems can safely be carried out by the responsible electrical engineer.Since this new development was designed only according to the latest standards, the required measuring values can be even more convenient stored with an App (iOS / Android) via Bluetooth on the mobile phone, saved to an SD card or, when work is completed, from the internal data memory via USB connection to a PC.

  • 6000 Series Digital I/O Modules

    Pacific Instruments, Inc.

    Series 6000 digital I/O modules record signals from frequency counters, flow meters, encoders, discrete transducers, IRIG time, etc. which are often part of the test environment. These digital signals are time aligned and recorded alongside the system’s analog measurements. High density digital inputs provide an opportunity to easily include facility controls like switches, valve positions, relays, lights, etc. along with the test data. Series 6000 digital I/O modules also provide outputs generated by user command or automatically by Sequence, Alarms or DSP. User generated outputs are accomplished in software while sequencers can be programmed prior to a test and initiated by program or hardware control. Alarm conditions preprogrammed on the analog side can automatically generate digital outputs which are typically connected to facility control systems or PLCs. A DSP adds powerful real-time processing and is appropriate for PID control loops, derived parameter calculations and a variety of other real-time operations.

Get Help